{"id":93267,"date":"2020-10-19T16:17:31","date_gmt":"2020-10-19T13:17:31","guid":{"rendered":"https:\/\/en.buradabiliyorum.com\/detecting-early-stage-failure-in-electric-power-conversion-devices\/"},"modified":"2020-10-19T16:17:31","modified_gmt":"2020-10-19T13:17:31","slug":"detecting-early-stage-failure-in-electric-power-conversion-devices","status":"publish","type":"post","link":"https:\/\/buradabiliyorum.com\/en\/detecting-early-stage-failure-in-electric-power-conversion-devices\/","title":{"rendered":"#Detecting early-stage failure in electric power conversion devices"},"content":{"rendered":"<p>&#8220;<strong>#Detecting early-stage failure in electric power conversion devices<\/strong>&#8221;<\/p>\n<div>\n<div class=\"article-gallery lightGallery\">\n<div data-thumb=\"https:\/\/scx1.b-cdn.net\/csz\/news\/tmb\/2020\/5f8d7f4bc9367.jpg\" data-src=\"https:\/\/scx2.b-cdn.net\/gfx\/news\/2020\/5f8d7f4bc9367.jpg\" data-sub-html=\"Figure 1. Acoustic emission (AE) was applied to monitor wear-out failure in discrete SiC Schottky barrier diode (SBD) devices with a Ag sinter die attachment, to successfully monitor the real-time progress of failure of Al ribbons for the first time. (a) Optical image of a SiC-SBD device. (b) Cross-sectional SEM image. (c) Experimental apparatus for power cycling tests and real-time AE monitoring. (d) Waveform of collected AE signal and its characteristic, including counts and amplitude. (e) Generation, propagation, and collection of AE signals (i.e., elastic waves) in power electronics during a power cycling test. Credit: Osaka University\">\n<figure class=\"article-img\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/scx1.b-cdn.net\/csz\/news\/800\/2020\/5f8d7f4bc9367.jpg\" alt=\"Detecting early-stage failure in electric power conversion devices\" title=\"Figure 1. Acoustic emission (AE) was applied to monitor wear-out failure in discrete SiC Schottky barrier diode (SBD) devices with a Ag sinter die attachment, to successfully monitor the real-time progress of failure of Al ribbons for the first time. (a) Optical image of a SiC-SBD device. (b) Cross-sectional SEM image. (c) Experimental apparatus for power cycling tests and real-time AE monitoring. (d) Waveform of collected AE signal and its characteristic, including counts and amplitude. (e) Generation, propagation, and collection of AE signals (i.e., elastic waves) in power electronics during a power cycling test. Credit: Osaka University\" width=\"800\" height=\"480\"\/><figcaption class=\"text-darken text-low-up text-truncate-js text-truncate mt-3\">\n                Figure 1. Acoustic emission (AE) was <a href=\"https:\/\/buradabiliyorum.com\/en\/category\/download-scripts-themes-apps\/\" data-internallinksmanager029f6b8e52c=\"9\" title=\"Download Scripts &amp; Themes &amp; Apps\" target=\"_blank\" rel=\"noopener\">app<\/a>lied to monitor wear-out failure in discrete SiC Schottky barrier diode (SBD) devices with a Ag sinter die attachment, to successfully monitor the real-time progress of failure of Al ribbons for the first time. (a) Optical image of a SiC-SBD device. (b) Cross-sectional SEM image. (c) Experimental apparatus for power cycling tests and real-time AE monitoring. (d) Waveform of collected AE signal and its characteristic, including counts and amplitude. (e) Generation, propagation, and collection of AE signals (i.e., elastic waves) in power electronics during a power cycling test. Credit: Osaka University<br \/>\n            <\/figcaption><\/figure>\n<\/div>\n<\/div>\n<p>Power electronics regulate and modify electric power. They are in computers, power steering systems, solar cells, and many other technologies. Researchers are seeking to enhance power electronics by using silicon carbide semiconductors. However, wear-out failures such as cracks remain problematic. To help researchers improve future device designs, early damage detection in power electronics before complete failure is required.<\/p>\n<p>                                                                                In a study recently published in <i>IEEE Transactions on Power Electronics<\/i>, researchers from Osaka University monitored in real time the propagation of cracks in a silicon carbide Schottsky diode during power cycling tests. The researchers used an analysis technique, known as acoustic emission, which has not been previously reported for this purpose.<\/p>\n<p>During the power cycling test, the researchers mimicked repeatedly turning the device on and off, to monitor the resulting damage to the diode over time. Increasing acoustic emission corresponds to progressive damage to aluminum ribbons affixed to the silicon carbide Schottsky diode. The researchers correlated the monitored acoustic emission signals to specific stages of device damage that eventually led to failure.<\/p>\n<p>&#8220;A transducer converts acoustic emission signals during power cycling tests to an electrical output that can be measured,&#8221; explains lead author ChanYang Choe. &#8220;We observed burst-type waveforms, which are consistent with fatigue cracking in the device.&#8221;<\/p>\n<div class=\"article-gallery lightGallery\">\n<div data-thumb=\"https:\/\/scx1.b-cdn.net\/csz\/news\/tmb\/2020\/5f8d7f5beae22.jpg\" data-src=\"https:\/\/scx2.b-cdn.net\/gfx\/news\/hires\/2020\/5f8d7f5beae22.jpg\" data-sub-html=\"Figure 2. After eliminating background AE noise\u2014including power on-off switching and ambient noise\u2014via noise-filtering, AE signals were successfully collected for the SiC devices during a power cycling test. (a) Lift-off failure analysis results of failed discrete SiC-SBD devices after a power cycling test. (b) Cross section of one pre-failure Al ribbon where many cracks were observed at the interface. (c) AE single monitoring was compared with the traditional failure monitoring method: using the forward voltage during the power cycling test. The results indicate that AE monitoring can be used to understand fatigue propagation in Al ribbons (i.e., the failure mechanism) and also as an early warning before catastrophic lift-off fracture for power electronic devices. Credit: Osaka University\">\n<figure class=\"article-img text-center\"><img decoding=\"async\" src=\"https:\/\/scx1.b-cdn.net\/csz\/news\/800\/2020\/5f8d7f5beae22.jpg\" alt=\"Detecting early-stage failure in electric power conversion devices\"\/><figcaption class=\"text-left text-darken text-truncate text-low-up mt-3\">\n                Figure 2. After eliminating background AE noise\u2014including power on-off switching and ambient noise\u2014via noise-filtering, AE signals were successfully collected for the SiC devices during a power cycling test. (a) Lift-off failure analysis results of failed discrete SiC-SBD devices after a power cycling test. (b) Cross section of one pre-failure Al ribbon where many cracks were observed at the interface. (c) AE single monitoring was compared with the traditional failure monitoring method: using the forward voltage during the power cycling test. The results indicate that AE monitoring can be used to understand fatigue propagation in Al ribbons (i.e., the failure mechanism) and also as an early warning before catastrophic lift-off fracture for power electronic devices. Credit: Osaka University<br \/>\n            <\/figcaption><\/figure>\n<\/div>\n<\/div>\n<p>The traditional method of checking whether a power device is damaged is to monitor anomalous increases in the forward voltage during power cycling tests. Using the traditional method, the researchers found that there was an abrupt increase in the forward voltage, but only when the device was near complete failure. In contrast, acoustic emission counts were much more sensitive. Instead of an all-or-none response, there were clear trends in the acoustic emission counts during power cycling tests.<\/p>\n<p>&#8220;Unlike forward voltage plots, acoustic emission plots indicate all three stages of crack development,&#8221; says senior author Chuantong Chen. &#8220;We detected crack initiation, crack propagation and device failure, and confirmed our interpretations by microscopic imaging.&#8221;<\/p>\n<p>To date, there has been no sensitive early-warning method for detecting fatigue cracks that lead to complete failure in silicon carbide Schottsky diodes. Acoustic emission monitoring, as reported here, is such a method. In the future, this development will help researchers determine why silicon carbide devices fail, and improve future designs in common and advanced technologies.\n                                                                                                                        <\/p>\n<hr\/>\n<div class=\"article-main__explore my-4 d-print-none\">\n<p>                                            Paper-thin gallium oxide transistor handles more than 8,000 volts\n                                        <\/p><\/div>\n<hr class=\"mb-4\"\/>\n<div class=\"article-main__more p-4\">\n                                                                                                <strong>More information:<\/strong><br \/>\n                                                ChanYang Choe et al. Real-time acoustic emission monitoring of wear-out failure in SiC power electronic devices during power cycling tests, <i>IEEE Transactions on Power Electronics<\/i> (2020). <a rel=\"nofollow noopener noreferrer\" target=\"_blank\" data-doi=\"1\" href=\"http:\/\/dx.doi.org\/10.1109\/TPEL.2020.3024986\">DOI: 10.1109\/TPEL.2020.3024986<\/a><\/p><\/div>\n<div class=\"d-inline-block text-medium my-4\">\n                                                Provided by<br \/>\n                                                                                                    Osaka University<br \/>\n                                                                                                        <a rel=\"nofollow noopener noreferrer\" target=\"_blank\" class=\"icon_open\" href=\"http:\/\/www.osaka-u.ac.jp\/en\"><br \/>\n                                                        <svg><use href=\"https:\/\/techx.b-cdn.net\/tmpl\/v2\/img\/svg\/sprite.svg#icon_open\" x=\"0\" y=\"0\"\/><\/svg><\/a><\/p><\/div>\n<p>                                        <!-- print only --><\/p>\n<div class=\"d-none d-print-block\">\n<p>                                                 <strong>Citation<\/strong>:<br \/>\n                                                 Detecting early-stage failure in electric power conversion devices (2020, October 19)<br \/>\n                                                 retrieved 20 October 2020<br \/>\n                                                 from https:\/\/techxplore.com\/<a href=\"https:\/\/buradabiliyorum.com\/en\/category\/news\/\" data-internallinksmanager029f6b8e52c=\"2\" title=\"News\" target=\"_blank\" rel=\"noopener\">news<\/a>\/2020-10-early-stage-failure-electric-power-conversion.html<\/p>\n<p>                                            This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no<br \/>\n                                            part may be reproduced without the written permission. The content is provided for information purposes only.<\/p><\/div>\n<\/p><\/div>\n<p><script id=\"facebook-jssdk\" async=\"\" src=\"https:\/\/connect.facebook.net\/en_US\/sdk.js\"><\/script><\/p>\n<blockquote>\n<p style=\"text-align: center;\">For forums sites go to <span style=\"color: #ff9900;\"><a style=\"color: #ff9900;\" href=\"https:\/\/forum.buradabiliyorum.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">Forum.BuradaBiliyorum.Com<\/a><\/span><\/strong>\n<\/p><\/blockquote>\n<blockquote>\n<p style=\"text-align: center;\"><strong>If you want to read more Like this articles, you can visit our <span style=\"color: #ff9900;\"><a style=\"color: #ff9900;\" href=\"https:\/\/en.buradabiliyorum.com\/science\/\" target=\"_blank\" rel=\"noopener noreferrer\">Science category.<\/a><\/span><\/strong><\/p>\n<\/blockquote>\n<p><span style=\"color: black;\"><a style=\"color: #ff9900;\" href=\"https:\/\/techxplore.com\/news\/2020-10-early-stage-failure-electric-power-conversion.html\" target=\"_blank\" rel=\"noopener noreferrer\">Source<\/a><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&#8220;#Detecting early-stage failure in electric power conversion devices&#8221; Figure 1. Acoustic emission (AE) was applied to monitor wear-out failure in discrete SiC Schottky barrier diode (SBD) devices with a Ag sinter die attachment, to successfully monitor the real-time progress of failure of Al ribbons for the first time. (a) Optical image of a SiC-SBD device&#8230;.<\/p>\n","protected":false},"author":1,"featured_media":93268,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"fifu_image_url":"https:\/\/scx2.b-cdn.net\/gfx\/news\/2020\/5f8d7f4bc9367.jpg","fifu_image_alt":"","footnotes":""},"categories":[16],"tags":[],"class_list":["post-93267","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sciencee"],"_links":{"self":[{"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/posts\/93267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/comments?post=93267"}],"version-history":[{"count":0,"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/posts\/93267\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/media\/93268"}],"wp:attachment":[{"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/media?parent=93267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/categories?post=93267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/buradabiliyorum.com\/en\/wp-json\/wp\/v2\/tags?post=93267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}